Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 18 de 18
Filter
1.
Acta ortop. bras ; 26(3): 175-178, May-June 2018. tab, graf
Article in English | LILACS | ID: biblio-949743

ABSTRACT

ABSTRACT Objective This study addresses functional data, pain, and the reoperation rate in patients undergoing primary total knee arthroplasty (TKA) during which the patella was or was not replaced. Methods Fifty-three knees were included, 18 with the patella replaced and 35 with the patella not replaced. WOMAC and SF-12 scores and knee pain were analyzed preoperatively and 3, 6, and 12 months after TKA. The reoperation rate was also evaluated. Results Both groups presented significant improvement in WOMAC score and pain at all postoperative follow-up appointments. There was no significant difference between the groups in all evaluated variables. Two subjects in the group did not undergo patellar replacement due to complaints of anterior knee pain after arthroplasty. There was no difference between the groups in relation to the reoperation rate. Conclusion Patients receiving patellar replacement during TKA did exhibit significant differences in the rate of reoperation, function, or pain when compared to patients in which the patella was replaced. Level of Evidence III; Cohort study.


RESUMO Objetivo Este estudo confronta dados funcionais, dor e taxa de re-operação de pacientes submetidos à ATJ primária, que substituíram e que não substituíram a patela. Métodos 53 joelhos, sendo 18 com a patela substituída e 35 com a patela não substituída. Womac, SF-12 e dor no joelho foram analisados no pré-operatório e após 3, 6 e 12 meses da ATJ. A taxa de re-operação também foi avaliada. Resultados Ambos os grupos apresentam melhora significativa no questionário Womac e dor em todos os seguimentos pós-operatórios. Não houve diferença significativa entre os grupos em todas as variáveis avaliadas. Dois sujeitos no grupo NÃO foram submetidos a substituição da patela devido a queixas de dor anterior no joelho após a artroplastia. Não houve diferença entre os grupos em relação a taxa de re-operação. Conclusão Pacientes submetidos a substituição da patela na ATJ não obtiveram diferença significativa quanto a taxa de reoperação, função e dor quando comparados aqueles que não substituíram. Nível de evidência III; Estudo Coorte.

2.
Rev. bras. ortop ; 52(5): 549-554, 2017. tab, graf
Article in English | LILACS | ID: biblio-899185

ABSTRACT

ABSTRACT Objective: Opening-wedge osteotomy of the proximal tibia is a widely performed procedure for treating medial gonarthrosis in active patients and in the presence of varus malalignment of the lower limb. The fixation method is controversial, and the use of conventional implants has been abandoned in favor of implants with more modern locking screws. The aim of the present clinical study was to assess the maintenance of the correction achieved in cases wherein fixation was performed using conventional implants., Methods: This retrospective study included 51 patients who underwent opening-wedge high tibial osteotomy wherein fixation was performed using conventional implants (4.5-mm DCP plate and non-locking screws). Radiological findings regarding patellar height, tibial slope, and varus correction postoperatively and after consolidation were analyzed to assess the maintenance of the correction achieved by osteotomy., Results: The mean loss of correction angle, calculated by the difference between the correction angle in the immediate postoperative period and that after consolidation, was 0.92° ± 0.9°. In addition, changes in patellar height determined by the Blackburne-Peel method and in the sagittal slope of the tibial plateau were not significant or clinically relevant. Conclusions: The use of conventional plates and screws is viable in the fixation of opening-wedge high tibial osteotomy because they provide enough stability to maintain the achieved correction until consolidation, without significant changes.


RESUMO Objetivo: A osteotomia em cunha de abertura da tíbia proximal é um procedimento amplamente feito para o tratamento da gonartrose medial em pacientes ativos e na presença de mau alinhamento em varo do membro inferior. O método de fixação é controverso e o uso de implantes convencionais foi substituído pelo uso de implantes com parafusos de bloqueio mais modernos. O objetivo do presente estudo clínico foi avaliar a manutenção da correção feita nos casos em que a fixação foi feita com implantes convencionais. Métodos: Este estudo retrospectivo incluiu 51 pacientes submetidos a osteotomia tibial alta em cunha de abertura em que a fixação foi feita com implantes convencionais (placa de DCP de 4,5 mm e parafusos não bloqueados). Os achados radiológicos referentes à altura da patela, à inclinação tibial e à correção do varo no pós-operatório imediato e após consolidação foram analisados para avaliar a manutenção da correção obtida pela osteotomia. Resultados: A perda de ângulo de correção média, calculada pela diferença entre o ângulo de correção no pós-operatório imediato e após a consolidação, foi de 0,92° ± 0,9°. Além disso, alterações na altura patelar, avaliadas pelo método de Blackburne-Peel, e na inclinação sagital do platô tibial não foram significativas ou clinicamente relevantes. Conclusão: O uso de placas e parafusos convencionais é uma opção viável na fixação da osteotomia tibial alta em cunha de abertura, pois proporciona estabilidade suficiente para manter a correção obtida até a consolidação, sem alterações significativas.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Knee , Osteoarthritis , Osteotomy , Retrospective Studies
3.
Radiol. bras ; 49(2): 69-74, Mar.-Apr. 2016. tab, graf
Article in English | LILACS | ID: lil-780927

ABSTRACT

Abstract Objective: To compare the diagnostic performance of the three-dimensional turbo spin-echo (3D TSE) magnetic resonance imaging (MRI) technique with the performance of the standard two-dimensional turbo spin-echo (2D TSE) protocol at 1.5 T, in the detection of meniscal and ligament tears. Materials and Methods: Thirty-eight patients were imaged twice, first with a standard multiplanar 2D TSE MR technique, and then with a 3D TSE technique, both in the same 1.5 T MRI scanner. The patients underwent knee arthroscopy within the first three days after the MRI. Using arthroscopy as the reference standard, we determined the diagnostic performance and agreement. Results: For detecting anterior cruciate ligament tears, the 3D TSE and routine 2D TSE techniques showed similar values for sensitivity (93% and 93%, respectively) and specificity (80% and 85%, respectively). For detecting medial meniscal tears, the two techniques also had similar sensitivity (85% and 83%, respectively) and specificity (68% and 71%, respectively). In addition, for detecting lateral meniscal tears, the two techniques had similar sensitivity (58% and 54%, respectively) and specificity (82% and 92%, respectively). There was a substantial to almost perfect intraobserver and interobserver agreement when comparing the readings for both techniques. Conclusion: The 3D TSE technique has a diagnostic performance similar to that of the routine 2D TSE protocol for detecting meniscal and anterior cruciate ligament tears at 1.5 T, with the advantage of faster acquisition.


Resumo Objetivo: Comparar o desempenho diagnóstico da técnica tridimensional turbo spin-eco (3D TSE) de ressonância magnética (RM) do joelho na detecção de rupturas meniscais e ligamentares em comparação com o protocolo bidimensional turbo spin-eco (2D TSE). Materiais e Métodos: A sequência 3D TSE foi adicionada ao protocolo de rotina 2D TSE em 38 pacientes que foram submetidos a cirurgia artroscópica do joelho em até três dias após a realização da RM. Usando os achados artroscópicos como referência padrão ouro, foram calculados o desempenho diagnóstico e a concordância entre os protocolos. Resultados: A técnica 3D TSE e o protocolo 2D TSE apresentaram, respectivamente, sensibilidade (93%/93%) e especificidade (80%/ 85%) semelhantes na detecção de rupturas do ligamento cruzado anterior, sensibilidade (85%/83%) e especificidade (68%/71%) semelhantes na detecção de rupturas do menisco medial, assim como sensibilidade (58%/54%) e especificidade (82%/92%) semelhantes na detecção de rupturas do menisco lateral. A concordância intraobservador entre os dois métodos foi de substancial a quase perfeita em todos os parâmetros avaliados para ambos os leitores. Conclusão: A técnica 3D- SE apresentou desempenho diagnóstico semelhante ao protocolo de rotina 2D TSE na detecção de rupturas meniscais e ligamentares em magneto de 1,5 T, com a vantagem de possibilitar uma redução significativa no tempo de aquisição.

4.
Acta ortop. bras ; 22(3): 159-162, 2014. tab, graf
Article in English | LILACS | ID: lil-716241

ABSTRACT

OBJECTIVE: Evaluate safety and reliability of internal fixator for the treatment of intra-articular and periarticular distal femur fractures. METHODS: Retrospective data evaluation of 28 patients with 29 fractures fixed with internal fixator was performed. There was a predominance of male patients (53.5%), with 52% of open wound fractures, 76% of AO33C type fractures, and a mean follow up of 21.3 months. Time of fracture healing, mechanical axis deviation, rate of infection and postoperative complications were registered. RESULTS: Healing rate was 93% in this sample, with an average time of 5.5 months. Twenty-seven percent of patients ended up with mechanical axis deviation, mostly resulting from poor primary intra-operative reduction. There were two cases of implant loosening; two implant breakage, and three patients presented stiff knee. No case of infection was observed. Healing rate in this study was comparable with current literature; there was a high degree of angular deviation, especially in the coronal plane. CONCLUSION: Internal fixators are a breakthrough in the treatment of knee fractures, but its use does not preclude application of principles of anatomical articular reduction and mechanical axis restoration. Level of Evidence II, Retrospective Study. .

5.
Acta ortop. bras ; 20(3): 136-138, 2012. ilus, tab
Article in Portuguese | LILACS | ID: lil-640104

ABSTRACT

OBJETIVO: Desenvolver um modelo experimental que permita estudar a regeneração de grandes falhas ósseas em condições de infecção. MÉTODO: Falhas ósseas segmentares de 15mm foram criadas cirurgicamente na ulna de 12 coelhos e inoculadas com 5x10(8) unidades formadoras de colônia (UFC) de S. aureus. O desbridamento da infecção foi realizado duas semanas após, seguida da aplicação sistêmica de gentamicina por quatro semanas. Os animais foram acompanhados por um período de 12 semanas para avaliação do controle da infecção e da regeneração óssea. RESULTADOS: A regeneração espontânea foi inferior a 25% do defeito na avaliação radiográfica e histológica. CONCLUSÃO: A Falha óssea infectada de 15mm na ulna de coelhos é incapaz de alcançar a regeneração completa sem tratamentos adicionais. Nível de Evidência V, Estudo experimental.


OBJECTIVE: Develop a model that allowed the study of bone regeneration in infection conditions. METHOD: A 15 mm defect was surgically created in the rabbit ulna and inoculated with 5x10(8) colony-forming units (CFU) of S. aureus. Surgical debridement was performed two weeks after and systemic gentamicin was administered for four weeks. Animals were followed up to 12 weeks to evaluate infection control and bone regeneration. RESULT: Bone regeneration was inferior to 25% of the defect in radiological and histological analysis. CONCLUSION: Infected bone defect of 15 mm in the rabbit ulna was unable to achieve full regeneration without further treatment. Level of Evidence V, Experimental Study.


Subject(s)
Rabbits , Bone Regeneration , Osteitis , Periosteum , Ulna , Fluorescence , Gentamicins , Histology , Models, Animal , Radiography
6.
Acta ortop. bras ; 19(1): 28-31, 2011. ilus
Article in Portuguese | LILACS | ID: lil-582362

ABSTRACT

OBJETIVO: Apresentar um novo sistema de acoplamento solidário entre chave e parafuso de interferência, assim como ensaios biomecânicos que avaliem a segurança de sua utilização. MÉTODOS: O novo sistema foi submetido a ensaios biomecânicos de torção. Foram realizados dois tipos de análise: torque máximo de inserção manual dos parafusos em osso bovino; ensaios destrutivos de torção do sistema em máquina INSTRON 55MT. Os mesmos testes foram realizados em um grupo controle utilizando um sistema de acoplamento já disponível no mercado. (Acufex®) RESULTADOS: Nos ensaios de inserção em fêmures bovinos as médias de valores aferidos com torquímetro digital foram 1,958 N/m para Acufex® e 2,563 N/m para FMRP. Considerando p<0,05, não houve diferença significativa (p=0,02) nos valores de torque máximo de inserção nos dois sistemas estudados. Os valores médios de torque máximo para deformar o parafuso foram de 15 N/m para o parafuso Acufex® e 13 N/m para o parafuso FMRP, portanto, sem diferença estatística (p>0,05). Ao avaliar a deformação angular, não houve diferença significativa entre os grupos de parafuso (p=0,15). CONCLUSÃO: O novo sistema de acoplamento para parafusos de interferência desenvolvido na FMRP-USP revelou resistência à torção comparável a sistema já disponível no mercado e regulamentado para uso internacional.


OBJECTIVE: To introduce a new coupling system between screw driver and interference screw, and biomechanical tests that validate the safety of its application. METHODS: The new system was submitted to biomechanical torsion assays. Two types of analysis were performed: maximum torque of manual insertion of the screws into bovine bone; destructive assays of torsion of the system using an INSTRON 55MT machine. The same tests were also performed on a control group, using a commercially available interference screw coupling system (Acufex®). RESULTS: In the tests on manual insertion of screws in bovine femurs, the average values found with a digital torque meter were 1.958 N/m for Acufex® and 2.563 N/m for FMRP. Considering p>0.05, there were no statistical differences between the two groups (p=0.02) in the values for maximum torque of insertion, in the two systems studied. The average values for maximum torque of torsion resisted by the screw were 15N/m for the Acufex® screw and 13N/m for the FMRP screw, again with no statistical differences between the two groups (p>0.05). In the evaluation of angular deformation, there was also no significant difference between the two screw types (p=0.15). CONCLUSION: The new coupling system for interference screws developed at FMRP-USP revealed a torsion resistance that is comparable with the system already available on the market and regulated for international use.


Subject(s)
Animals , Cattle , Anterior Cruciate Ligament , Bone Screws , Anterior Cruciate Ligament/surgery , Biomechanical Phenomena , Equipment Safety , Femur , Knee/surgery , Orthopedic Equipment
7.
Rev. bras. ortop ; 46(1): 27-30, 2011. ilus
Article in Portuguese | LILACS | ID: lil-596351

ABSTRACT

OBJETIVO: Relatar os resultados iniciais com o uso de nova técnica para a fixação de enxerto ósseo em falhas ósseas tibiais não contidas em pacientes submetidos à prótese total de joelho. MÉTODOS: Seis pacientes com deformidade grave em varo do joelho que, após a realização dos cortes e balanço ligamentar, ainda apresentavam falhas ósseas avançando até à margem do corte tibial e que comprometiam a estabilidade do implante, foram submetidos a uma nova técnica de fixação. RESULTADOS: Cinco dos pacientes apresentaram bom resultado clínico, com integração do enxerto em até 12 semanas. Um paciente apresentou complicação clínica com deiscência da ferida e exposição da prótese, evoluindo para a retirada do implante e artrodese do joelho. CONCLUSÃO: A osteossíntese de suporte como método de fixação do enxerto é uma opção viável para o tratamento das falhas ósseas tibiais. A técnica proposta certamente necessita de mais estudos para a sua validação.


OBJECTIVE: To report the initial results from the use of a new technique for fixation of bone grafts in uncontained tibial bone defects in patients undergoing total knee prosthesis implantation. METHODS: Six patients with severe varus deformity of the knee who, after cuts and ligament balancing had been performed, still presented bone deficiencies that reached the edge of the tibial cut and compromised the implant stability, underwent a new fixation technique. RESULTS: Five of the patients had good clinical results, with integration of the graft within 12 weeks. One patient presented clinical complications with wound dehiscence and implant exposure, which evolved to the need for implant removal and knee arthrodesis. CONCLUSION: Support osteosynthesis as a graft fixation method is a viable option for treating tibial bone deficiencies. The proposed technique certainly needs further studies for its validation.


Subject(s)
Humans , Male , Female , Arthroplasty , Bone Transplantation , Knee Prosthesis
8.
Rev. bras. ortop ; 46(supl.1): 9-12, 2011. ilus, tab
Article in Portuguese | LILACS | ID: lil-596370

ABSTRACT

OBJETIVO: Apresentar os resultados de pesquisa Datafolha, realizada no período de 23 de setembro a 18 de outubro de 2010, sobre as condições existentes para o exercício profissional na área do trauma ortopédico no Brasil. MÉTODOS: pesquisa quantitativa, com abordagem telefônica dos entrevistados, por meio de sorteio aleatório de membros da Sociedade Brasileira de Ortopedia e Traumatologia, em cadastro contendo mais de 7.000 nomes. As entrevistas foram realizadas mediante aplicação de questionário estruturado, com aproximadamente 25 minutos de duração. RESULTADOS: 97 por cento dos entrevistados dedica parte do seu tempo ao trauma ortopédico. 87 por cento dos entrevistados exercem outra sub-especialidade, que não o trauma ortopédico. Na média dos atendimentos no país, 43 por cento dos pacientes pertencem à rede pública de saúde e 41 por cento pertencem à rede de convênios. O uso de implantes importados ocorre na minoria das situações (36 por cento) e 83 por cento dos médicos que utilizam ambos os tipos de implantes julga que os nacionais apresentam qualidade inferior. 61 por cento dos entrevistados julga a qualidade do atendimento em serviços públicos regular, ruim ou péssima. Metade dos entrevistados declara ter problemas para a liberação de suas solicitações de procedimentos junto aos planos de saúde em pelo menos 25 por cento das vezes em que encaminham tais pedidos. CONCLUSÃO: O trauma ortopédico é uma especialidade exercida pela grande maioria dos ortopedistas brasileiros. A estrutura dos serviços públicos é considerada insatisfatória pela maioria dos ortopedistas entrevistados. A maioria dos ortopedista deseja uma reformulação nos honorários médicos e na infra-estrutura de serviços.


OBJECTIVES: The aim of this article is to present the data collected by Datafolha institute, from September 23rd. through October 18th. 2010 about orthopedic trauma care in Brazil. METHOD: A quantitative analysis based on telephonic interviews has been performed. From Brazilian Orthopedic Society database containing more than 7000 records. A structured query has been applied and the interview lasted around 25 minutes. RESULTS: 97 percent of interviewees dedicate part of his/her time to orthopedic trauma. 87 percent of all interviewees dedicate his/her time to more than one sub-specialty. The majority of orthopedic trauma patients comes from government insurance system (43 percent), while 41 percent of patients come from private insurance. 61 percent of all interviewees think that the quality of public health system could be rated as unsatisfactory. Northeast of Brazil is the place where the majority of patients are from public health system and where we have highest rates of dissatisfaction (85 percent) related to available infrastructure for orthopedic trauma care. Half of all interviewed individuals have problems for getting private insurance authorization previously to a surgery. CONCLUSIONS: Orthopedic trauma is a specialty practiced by the vast majority of orthopedic surgeons in our country. Neither the infrastructure nor the salaries satisfy the majority or orthopedic surgeons dedicated to trauma care.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Emergency Medical Services , Evaluation of the Efficacy-Effectiveness of Interventions , First Aid , Multiple Trauma , Outcome and Process Assessment, Health Care , Patient Satisfaction , Wounds and Injuries , Health Services Research
9.
Rev. bras. ortop ; 46(supl.1): 44-47, 2011. tab
Article in Portuguese | LILACS | ID: lil-596377

ABSTRACT

OBJETIVO: Estabelecer se há correlação entre o momento da cirurgia e a ocorrência de complicações intra e pós- operatórias no tratamento das fraturas trocanterianas do fêmur no idoso. MÉTODO: Estudo retrospectivo avaliando o histórico de 281 pacientes operados entre 2000 e 2009 no Hospital das Clinicas da FMRP-USP. As variáveis avaliadas foram: sexo, idade, data, mecanismo do trauma, momento da admissão, tipo da fratura, complicações pré e pós- operatórias, tempo entre o trauma e a cirurgia, horário e duração da cirurgia, implante utilizado, Tip Apex Distance (TAD), tempo de hospitalização, re-operações. De acordo com o horário da cirurgia os casos foram divididos em dois grupos: Horário Comercial (7:00 - 17:00) x Horário Plantão (17:01 - 6:59). RESULTADOS: Houve um predomínio de cirurgias no horário comercial, na proporção aproximada de 5:1. O intervalo de tempo médio entre a data do trauma e a cirurgia foi de três dias. Não houve diferença estatística entre os grupos (hora comercial x plantão) relacionada ao TAD médio, tipo da fratura, implante, complicações sistêmicas e mortalidade em um ano. O tempo médio entre o trauma e a cirurgia foi três dias. CONCLUSÕES: Para pacientes que são admitidos ou operados com mais de 24 horas decorridas do trauma, o horário da cirurgia não se mostrou uma variável relevante, no que diz respeito à ocorrência de complicações per operatórias. Em nossa realidade, é preferível realizar a fixação destas fraturas em horário comercial, dispondo de completa infra-estrutura de recursos humanos e técnicos.


OBJECTIVE: This study aimed to verify if there is any relationship between the time of surgery and per operative complications in the treatment of intertrochanteric femoral fractures. METHOD: The records of 281 patients operated between the years of 2000 and 2009 were evaluated retrospectively. The variables taken into account were sex, age, date and mechanism of injury, time of admission, type of fracture (AO classification), pre and post-operative complica- tions, delay between trauma and surgery time, time and duration of surgery, implant used, Tip Apex Distance (TAD), and hospital stay. The cases were divided according with the start time of surgery into two groups: usual working hours (7:00 - 17:00) x non-usual working hours (17:01 - 6:59). RESULTS: Most of the surgeries were performed during working hours, at an approximate ratio of 5:1. The average time between trauma and surgery was three days. There was no statistical difference between groups (working vs. non-working hours) in relation to the average TAD, type of fracture, implant, clinical complications and mortality in one year. CONCLUSIONS: Our study demonstrates that for patients that are not admitted or operated within the first 24 hours from trauma, the time of surgery is not a relevant variable, regarding to per-operative complications. In our reality, there is no reason for operating such patients out of working hours, when all necessary resources are available.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged, 80 and over , Hip Fractures/surgery , Hip Fractures/rehabilitation , Intraoperative Complications , Surgical Procedures, Operative
11.
Rev. bras. ortop ; 46(supl.1)2011.
Article in Portuguese | LILACS | ID: lil-596383
12.
Acta ortop. bras ; 18(4): 224-229, 2010. ilus, graf, tab
Article in English, Portuguese | LILACS | ID: lil-554652

ABSTRACT

OBJETIVO: Avaliar o impacto da integridade da cortical lateral osteo-tomia alta de tíbia (OAT) com cunha de abertura. MÉTODOS: Modelos experimentais artificiais em poliuretano foram fixados com placa DCP® 4,5mm. Cunhas de abertura foram confeccionadas para simular a distração da osteotomia alta da tíbia. Realizadas falhas na cortical lateral para simular fraturas e fixadas com diferentes tipos de parafusos. Ensaios de torção e compressão axial foram realizados. 04 diferentes grupos foram constituídos. RESULTADOS: As medidas de torção registradas no grupo com cortical íntegra foram superiores àquelas obtidas no grupo com cortical rompida (p<0,001) e estatisticamente equivalentes aos grupos com cortical rompida associado à parafuso de estabilização lateral de compressão ou de posição (p>0,05). As medidas de compressão obtidas no grupo com cortical íntegra foram superiores aos demais grupos (p<0,001). Em torção e compressão não houve diferença estatística entre os tipos de parafuso de estabilização lateral (p>0,05). CONCLUSÃO: A cortical lateral íntegra agrega estabilidade às osteotomias com cunha de abertura medial. Modelo com cortical íntegra evidenciou superioridade biomecânica em rigidez nos ensaios de torção e compressão. Nos ensaios torcionais, os modelos com falha de continuidade cortical com parafusos de estabilização lateral de compressão ou de posição apresentaram equivalência aos modelos com cortical íntegra.


OBJECTIVE: To evaluate the role of lateral tibial cortex integrity in open wedge tibial osteotomy (OWTO). METHODS: Experimental models of polyurethane fibers, simulating tibial models and modified with open wedge osteotomies were fixed with DCP® straight 4.5 mm plates. Four groups were constituted: two with cortical integrity and two with a gap in the lateral tibial cortex. Biomechanical analysis of torsion and axial compression were performed. RESULTS: The measures of twist recorded in the group with cortical integrity were higher than those obtained in the group with noncontinuous cortices (p <0.001). The groups with cortical gap on the lateral side that were fixed with screws had a biomechanical behavior comparable to the group with cortical integrity. Measures of compression obtained in the group with full cortical integrity were greater than those of other groups (p <0.001). In torsion and compression, no statistical difference between lag and position screws on the lateral cortical was demonstrated (p>0.05). CONCLUSION: Integrity of lateral tibial cortex adds stability to open wedge tibial osteotomies. Models with lateral cortical integrity demonstrated superiority in biomechanical stiffness even under torsion or compression. In torsion tests, models with a gap on the lateral cortex, fixed with a lag or position screw to promote lateral stabilization had similar biomechanical behavior to those with lateral cortex integrity.


Subject(s)
Bone Plates , Bone Screws , Tibial Fractures/rehabilitation , Osteotomy/rehabilitation , Polyurethanes , Tibial Fractures , Biomechanical Phenomena , Tibial Fractures
13.
Acta ortop. bras ; 18(1): 31-34, 2010. ilus
Article in Portuguese | LILACS | ID: lil-545321

ABSTRACT

OBJETIVO: Determinar as características de eluição da gentamicina. MÉTODO: 480mg de gentamicina foram adicionadas a 40g de cimento ósseo. Dez corpos de teste semelhantes foram produzidos e imersos individualmente em solução salina tamponada por 28 dias. Amostras dos dias 1, 2, 7, 14, 21 e 28 foram analisadas pelo método de imunofluorescência polarizada. RESULTADO: A maior parte da gentamicina foi liberada do cimento nas primeiras 24 horas. Uma queda gradual se deu do 2º ao 14º dia. No 28º dia, a maior parte das amostras não apresentava mais níveis detectáveis do antibiótico. CONCLUSÃO: A mistura liberou quantidades elevadas e em doses terapêuticas do antibiótico de forma previsível ate o décimo quarto dia.


OBJECTIVE: To determine the elution characteristics of the antibiotic (gentamicin) mixed with bone cement. METHODS: 480mg of gentamicin was added to 40g of bone cement. Ten specimens were immersed in buffered saline solution for 28 days. Samples of days 1, 2, 7, 14, 21 and 28 were analyzed by the fluorescence polarization immunoassay method. RESULTS: Most of the gentamicin was eluted from the cement in the first 24 hours. A gradual downslide occurred between days 2 and 14. By the 28th day, there was no trace of the antibiotic. CONCLUSION: The mixture released high amounts of the antibiotic in a predictable (therapeutic) manner during at least fourteen days.


Subject(s)
Antibiotic Prophylaxis , Bone Cements/therapeutic use , Gentamicins/administration & dosage , Gentamicins/therapeutic use , Treatment Outcome , Infections/therapy , Osteomyelitis
14.
Rev. bras. ortop ; 44(6): 468-474, 2009. ilus
Article in Portuguese | LILACS | ID: lil-538060

ABSTRACT

As fraturas do planalto tibial são lesões articulares cujos princípios de tratamento envolvem a redução anatômica da superfície articular e a restauração funcional do eixo mecânico do membro inferior. Contribuem para a tomada de decisões no tratamento dessas fraturas o perfil do paciente, as condições do envelope de tecidos moles, a existência de outros traumatismos associados e a infraestrutura disponível para abordagens cirúrgicas. Para as fraturas de alta energia, o tratamento estagiado, seguindo o princípio do controle de danos, tem como prioridade a manutenção do alinhamento do membro enquanto se aguarda a resolução das más condições de tecidos moles. Já nos traumas de baixa energia, desde que os tecidos moles não sejam um fator adverso, o tratamento deve ser realizado em tempo único, com osteossíntese definitiva. Fixação estável e movimento precoce são variáveis diretamente relacionadas com os melhores prognósticos. Desenvolvimentos recentes, como os implantes com estabilidade angular, substitutos ósseos e imagens tridimensionais para controle intraoperatório, deverão contribuir para cirurgias menos invasivas e melhores resultados.


Tibial plateau fractures are joint lesions that require anatomical reduction of joint surface and functional restoration of mechanical axis of a lower limb. Patient profile, soft tissue conditions, presence of associated injuries and the available infrastructure for the treatment all contribute to the decision making about the best treatment for these fractures. High-energy fractures are usually approached in a staged manner respecting the principle of damage control, and are primarily targeted to maintain limb alignment while the resolution unfavorable soft tissue conditions is pending. Low-energy trauma can be managed on a single-stage basis, provided soft tissues are not an adverse factor, with open reduction and internal f-ixation. Stable fixation and early painless joint movement are related to a better prognosis. New developments as locked plates, bone replacements, intraoperative 3D imaging are promising and will certainly contribute for less invasive procedures and better outcomes.


Subject(s)
Humans , Tibial Fractures/complications , Tibial Fractures/diagnosis , Tibial Fractures/therapy
15.
Rev. bras. ortop ; 43(3): 83-89, mar. 2008. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-483395

ABSTRACT

OBJETIVO: Avaliar os efeitos mecânicos da inclinação do parafuso excêntrico sobre a compressão axial com placa. MÉTODOS: Corpos de prova artificiais simulando fragmentos de osso diafisário foram fixados com placa DCP® de 4,5mm de sete orifícios. Uma célula de carga registrou as forças de compressão axial no intervalo entre os fragmentos. Guias de perfuração excêntrica com inclinações em relação ao plano longitudinal e transversal da placa foram confeccionados para o experimento. A compressão foi medida em dois diferentes sítios do foco de fratura virtual. De acordo com a magnitude da inclinação e sua direção em relação ao orifício da placa, oito diferentes grupos foram constituídos. Os ensaios mecânicos registraram a força máxima e a força máxima efetiva. RESULTADOS: A inclinação do parafuso em direção contrária à da rampa de deslizamento do orifício da placa foi acompanhada de diminuição nos valores médios de força máxima e força máxima efetiva de compressão 0º > 10ºi (p < 0,001), 0º > 20ºi (p < 0,001), 0º > 25ºi (p < 0,001). CONCLUSÃO: Em modelo experimental, utilizando-se placas do tipo DCP® não pré-tensionadas, a inclinação na inserção de parafusos excêntricos promoveu alterações nos valores médios da força de compressão axial. Houve diferenças significativas (p < 0,05) para menos na compressão axial obtida na cortical subjacente à placa, quando da inserção de parafusos inclinados no plano longitudinal com direção oposta à da rampa de deslizamento do orifício DCP®.


OBJECTIVE: To evaluate the mechanical effects of sloping the load screw on the axial compression with a dynamic plate. METHODS: Artificial parts simulating shaft fragments were fixated with a 4.5 mm, 7 orifice DCP® plate. A load cell recorded axial compression loads in the space between fragments. Eccentric perforation guides with inclinations to the longitudinal and transversal plan of the plate were made for the experiment. Compression was measured in two different sites of the virtual fracture focus. Eight different groups were formed according to the magnitude of inclination and its direction based on the plate orifice. Mechanical assays recorded maximum load and effective maximum load. RESULTS: Screw inclination contrary to the plate orifice sliding slope was related to decreased mean values of maximum compression load and maximum effective compression load 0º > 10ºi (p < 0,001), 0 > 20ºi (p < 0,001), 0º > 25ºi (p < 0,001). CONCLUSION: In an experimental model, using non pre-stressed DCP® plates, the inclination upon inserting load screws brought about changes in the mean values of axial compression load. There significant differences (p < 0,05) to lower axial compression obtained in the cortical adjacent to the plate when the screws were inserted in inclination with the longitudinal plane in the opposite direction of the sliding slope of the DCP® orifice.


Subject(s)
Biomechanical Phenomena , Bone Plates , Bone Screws , Fracture Fixation, Internal/methods
16.
Rev. bras. ortop ; 36(4): 125-131, abr. 2001. ilus, tab, graf
Article in Portuguese | LILACS | ID: lil-334912

ABSTRACT

Os polímeros absorvíveis constituem uma nova etapa nas pesquisas destinadas ao desenvolvimento do implante ortopédico ideal. Os autores realizaram trabalho experimental no qual compararam as propriedades mecânicas e o comportamento biológico de dois polímeros distintos, a poliparadioxanona, disponível comercialmente em nosso meio mediante importação (Orthosorb), e a poliuretana da mamona, obtida em território nacional a baixo custo. Pinos de aproximadamente 1,3mm de diâmetro foram submetidos a ensaios mecânicos de cisalhamento, nos quais foram analisadas propriedades tais como a carga máxima, carga no limite de proporcionalidade, resistência e rigidez destes implantes. Os resultados foram analisados mediante o teste t de Student não pareado, com nível de significância fixado em 5 por cento (p < 0,05). A superioridade dos pinos de poliparadioxanona foi evidente em todas as propriedades mecânicas estudadas, exceto a rigidez. O comportamento biológico desses pinos foi estudado em coelhos. Submeteram-se 31 animais da raça Nova Zelândia a osteotomia do côndilo femoral medial direito no plano axial. A fixação do segmento osteocondral foi realizada com pinos absorvíveis, sendo os animais diferenciados em dois grandes grupos, de acordo com o polímero utilizado na cirurgia. O sacrifício dos animais ocorreu às três, seis e 12 semanas de pós-operatório, quando os espécimes femorais foram submetidos a estudo macroscópico, radiográfico e histológico. Nos diferentes períodos estudados neste experimento, a poliparadioxanona apresentou comportamento biológico superior ao da poliuretana da mamona no que diz respeito a bioabsorção dos pinos e à osteogênese em seus sítios de implantação.


Subject(s)
Animals , Female , Rats , Biopolymers/therapeutic use , Fracture Fixation, Internal , Shoulder Fractures
17.
Acta ortop. bras ; 8(4): 202-8, out.-dez. 2000. tab, graf
Article in Portuguese | LILACS | ID: lil-283813

ABSTRACT

O ligamento cruzado anterior é um elemento importante na estabilizaçäo do joelho. A ruptura do ligamento cruzado anterior correlacionam-se lesöes meniscais e condrais, com possíveis implicaçöes funcionais para a articulaçäo. O tratamento da lesäo do ligamento cruzado anterior tem como objetivo principal a estabilizaçäo funcional do joelho, podendo ser conservador ou cirúrgico. Idade fisiológica do paciente, nível de prática esportiva e lesöes articulares associadas säo elementos críticos na escolha da abordagem terapêutica. O tratamento conservador é fundamentado na mudança de atividades físicas, na prevençäo de esportes de contato e no fortalecimento muscular. Para os indivíduos que desejam retornar ao seu nível normal de práticas esportivas o tratamento cirúrgico constitui o consenso. A técnica cirúrgica mais difundida para o tratamento das lesöes do ligamento cruzado anterior consiste na sua substituiçäo pelo terço central do ligamento patelar. Esta popularidade se deve às características biomecânicas e de fixaçäo deste enxerto. Os enxertos homólogos constituem uma alternativa atratente na cirurgia ligamentar do joelho. As principais vantagens desta técnica cirúrgica säo a menor morbidade ao paciente, menor tempo cirúrgico, melhor cosmese e menor índice de dor pós-operatório. Esta técnica tem como aspectos polêmicos o risco de reaçöes imunológicas e o potencial de transmissäo de doenças infecciosas.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Anterior Cruciate Ligament/surgery , Knee/physiopathology , Patellar Ligament , Transplantation, Autologous/methods , Transplantation, Homologous/methods
18.
Rev. bras. ortop ; 29(6): 411-5, jun. 1994. ilus, tab
Article in Portuguese | LILACS | ID: lil-199717

ABSTRACT

Säo analisados, em caráter prospectivo e sob o ponto de vista funcional, os resultados da artrodese do punho com fixaçäo interna rígida em nove pacientes, totalizando dez punhos, com seguimento mínimo de seis meses de pós-operatório. Utilizou-se um método de avaliaçäo abrangente que resume, basicamente, todo o tipo de funçäo manual possível. Conluiu-se que a artrodese do punho é um método terapêutico aplicável a diversas afecçöes que impliquem em dor e instabilidade desta articulaçäo, näo afetando significativamente a funçäo global do membro superior, embora resulte em considerável perda da força de preensäo máxima de mäo e requeira movimentos compensatórios do ombro e do cotovelo.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Arthrodesis/instrumentation , Fracture Fixation, Internal , Wrist Injuries/surgery , Evaluation Study , Prospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL